FAQFAQ   SearchSearch   MemberlistMemberlist   UsergroupsUsergroups   RegisterRegister   ProfileProfile   Log in to check your private messagesLog in to check your private messages   Log inLog in 

  ads
Does this look right?? Cooling issue

 
Post new topic   Reply to topic     Forum Index -> Subaru Power
View previous topic :: View next topic  
Author Message
tommyhove
Initiate Jedi
Initiate Jedi


Joined: 04 Feb 2013
Posts: 28

PostPosted: Tue Aug 09, 2016 6:31 pm    Post subject: Does this look right?? Cooling issue Reply with quote

This is basically how my cooling system looks, the pipe to the thermostat from the rad isn't getting hot, do you think it's just a sticking stat?

Back to top
View user's profile Send private message
dialarcs
Wannabe
Wannabe


Joined: 21 Jul 2016
Posts: 7

PostPosted: Wed Aug 10, 2016 2:21 pm    Post subject: Reply with quote

Have a read through this, may help you out, your setup looks right according to RJES diagram.

http://www.rjes.com/html/filling_procedure.html

How long are you waiting for it to warm up?
Is the heater pipes warming up?
Is the engine getting too hot?
Is the rad tilting up and air locking?

It will take a while before the stat opens to allow flow to the rad.

Probably silly questions that you've already thought of.
Back to top
View user's profile Send private message
tommyhove
Initiate Jedi
Initiate Jedi


Joined: 04 Feb 2013
Posts: 28

PostPosted: Wed Aug 10, 2016 5:50 pm    Post subject: Reply with quote

It seems I've got a blockage somewhere in the rad, the side it flows out of doesn't get anywhere near as hot as the in side.
Back to top
View user's profile Send private message
tommyhove
Initiate Jedi
Initiate Jedi


Joined: 04 Feb 2013
Posts: 28

PostPosted: Thu Aug 11, 2016 7:55 am    Post subject: Reply with quote

Right, rad is fine

Any suggestions??
Back to top
View user's profile Send private message
tommyhove
Initiate Jedi
Initiate Jedi


Joined: 04 Feb 2013
Posts: 28

PostPosted: Thu Aug 11, 2016 2:33 pm    Post subject: Reply with quote

here's a pic that better shows whats happening


Back to top
View user's profile Send private message
Kai
Jedi Guardian
Jedi Guardian


Joined: 14 Nov 2008
Posts: 1226
Location: Village life.... Enter the Vale

PostPosted: Fri Aug 12, 2016 11:55 pm    Post subject: Reply with quote

Clearly there is an airlock. Unless your water pump or temperature stat is buggared. The coolant circuit is almost identical to mine.

I know my mate had loads of trouble bleeding a bay with ej20 turbo. He back it up a pile of dirt raising the back end and left it running. It'll take 20-30 minutes to warm up on idle before the stat will open.

Also we're assuming that you heater matrix is open and free of air. Mine always worked well and was self bleeding until I decided to install a heater. I ended up having to install a small bleeder pipe and T'd that into the black line on your diagram.
_________________
Think......

Don't sleep and drive!!!
Back to top
View user's profile Send private message
tommyhove
Initiate Jedi
Initiate Jedi


Joined: 04 Feb 2013
Posts: 28

PostPosted: Mon Aug 15, 2016 1:57 pm    Post subject: Reply with quote

cheers dude I'm relatively new to this and its doing my head in.

i know the stat is working as I've had it out and checked.

if the water pump was knackered would i still see water flowing in the expansion tank? it seems to be mainly from the black pipe in the diagram?
Back to top
View user's profile Send private message
Kai
Jedi Guardian
Jedi Guardian


Joined: 14 Nov 2008
Posts: 1226
Location: Village life.... Enter the Vale

PostPosted: Mon Aug 15, 2016 5:33 pm    Post subject: Reply with quote

If the black pipe is flowing coolant then I'd say you have an airlock in the radiator pipe between the black pipe and the stat.

Try back flowing it with hose pipe on the radiator return pipe perhaps. Or more the connection for the black pipe closer to the stat.
_________________
Think......

Don't sleep and drive!!!
Back to top
View user's profile Send private message
tommyhove
Initiate Jedi
Initiate Jedi


Joined: 04 Feb 2013
Posts: 28

PostPosted: Wed Aug 17, 2016 8:00 am    Post subject: Reply with quote

I think it may be sorted, my dad put a brass bleed valve at the front of the rad,

jacked back up and ran it for half hour or so.

jacked front up and bled it through new valve.


all seems to be OK and you can feel the pressure difference in the pipes from before when they were rock solid


.... for now it seems fine.
Back to top
View user's profile Send private message
Juraf29
Wannabe
Wannabe


Joined: 04 Feb 2021
Posts: 1

PostPosted: Fri Feb 05, 2021 3:20 am    Post subject: Reply with quote

Kai wrote:
Clearly there is an airlock. Unless your water pump or temperature stat is buggared. The coolant circuit is almost identical to mine.

I know my mate had loads of trouble bleeding a bay with ej20 turbo. He back it up a pile of dirt raising the back end and left it running Cartons déménagement pas cher. It'll take 20-30 minutes to warm up on idle before the stat will open.

Also we're assuming that you heater matrix is open and free of air. Mine always worked well and was self bleeding until I decided to install a heater. I ended up having to install a small bleeder pipe and T'd that into the black line on your diagram.

He did well I think. Because we have to leave the rear raised if we want to keep the wheels in good condition.
Back to top
View user's profile Send private message
Display posts from previous:   
Post new topic   Reply to topic     Forum Index -> Subaru Power All times are GMT
Page 1 of 1

 
Jump to:  
You cannot post new topics in this forum
You cannot reply to topics in this forum
You cannot edit your posts in this forum
You cannot delete your posts in this forum
You cannot vote in polls in this forum


Powered by phpBB © 2001, 2005 phpBB Group
NOT SO
SHABBY
INTERIORS
CLICK ME



ads

VanMonst

VWHERT



NOT SO
SHABBY
INTERIORS
CLICK ME



ads


ads

ads


CarBuilderSolutions





ads